Precision Timing for Reliable Power.  Simplified.
SER-3200 with I-heart-1588 logo

Ordering Info: [ Price List ]
Catalog No. Description
SER-3200-P2X2CyTime Event Recorder, 32 inputs (24Vdc)
SER-3200-PTPCyTime Event Recorder, 32 inputs, plus PTP
SER-3200-32GBCyTime Event Recorder, 32 inputs, PTP + 32GB
SER-2408-P2X2CyTime Event Recorder, 24 in / 8 outputs (24Vdc)
SER-2408-PTPCyTime Event Recorder, 24 in / 8 outputs, PTP
SER-2408-32GBCyTime Event Recorder, 24 in / 8 outputs, PTP + 32GB
PTP-UPGRADEPTP Field Upgrade Kit for CyTime SER-3200/SER-2408
EZC-IRIG-BEZ Connector for SER, IRIG-B input
EZC-DCF77EZ Connector for SER, DCF77 input
PLX-5VPTP Legacy Interface OUT (5V output)
PLX-24VPTP Legacy Interface OUT (24V output)
  
ECM POY logo CSE POY logo CSE POY Silver
  

CyTime™ Sequence of Events Recorders—SER-3200/SER-2408

Know what happened and when—to 1 millisecond! CyTime Sequence of Events (SoE) Recorders, models SER-3200/SER-2408 record status changes of 32 channels, time-stamped to 1ms.   Time synchronization is achieved via PTP (IEEE 1588), IRIG-B, DCF77, NTP, Modbus TCP or an RS-485 signal from another SER.   An embedded web server allows setup over a network using a standard browser, plus easy access to all events, status and even custom pages you create (or we'll do them for you).

CyTime Event Recorders are the first to use PTP to achieve "hi-res" time synchronization over Ethernet for commercial/industrial applications. One CyTime SER serves as PTP master and all other CyTime SER devices sync automatically within 100 microseconds—without special Ethernet switches.  Since most relays or meters don’t yet support PTP, an SER-3200/2408 also serves as time-sync master for these devices, generating the legacy protocol required.  This eliminates the redundant cabling between equipment lineups normally needed for 1ms timing.

Markets/Applications:

Data Centers

CyTime Event Recorders enable Sequence of Events Recording (SER) in modern data center Electrical Power Monitoring Systems (EPMS). [ More ]

Hospitals

Emergency Power Supply Systems (EPSS) in hospitals use CyTime Event Recorders in automatic test and reporting systems to ensure reliable backup power and document compliance with testing regulations. [ More ]

Power SCADA for Process Industries

The SER-3200/SER-2408 offer precision event recording for supervisory control and data acquisition systems in continuous processes such as refineries and water treatment plants. [ More ]

Microgrids and Alternative Energy

CyTime Event Recorders provide critical data for root-cause analysis in microgrids and alternative energy networks, such as wind, solar and fuel cells. When used with compatible power monitors or protective relays, the SER-3200/SER-2408 trigger waveform captures coincident with events, for advanced diagnostics and preventive maintenance. [ More ]

Reliable operation.   Dedicated event-processor captures cascading events reliably—zero-blind-time—independent of network traffic or other demands on processor bandwidth (unlike some relays, meters and PLCs).

Know breaker opening times.    The SER-3200/2408 records the exact time of the initiating event (e.g., relay trip) and resulting state (tripped) to calculate breaker opening times under different load conditions.  [ See Tech Note for details ]

Hi-res (1-ms) time-sync over Ethernet via PTP.   Just set the first SER time, all other SERs sync automatically using PTP (IEEE 1588).

Simple setup.   An embedded web server hosts intuitive web pages to facilitate setup and monitoring—no software to install.

Advanced troubleshooting.   Trigger output to command a compatible power meter to capture current and voltage waveforms coincident with an event.

  • Time-stamped event recording for 32 channels, 1ms accuracy
  • Isolated digital inputs with configurable filter, debounce and chatter
  • Up to 8192 Events stored in non-volatile memory
  • Ethernet connectivity, Modbus TCP and web technologies
  • GPS time sync via PTP (IEEE 1588 Master/Slave), IRIG-B or DCF77
  • Time output (IRIG-B, DCF77, ASCII) to other devices
  • Other time-sync options include NTP, Modbus TCP or Inter-SER (RS-485)
  • High-speed trigger to capture waveforms by a compatible power meter
  • Open/close relay outputs over an Ethernet network (Modbus TCP)
  • Operations counters with date/time of last reset, per channel